logo
90 試験結果

"material handling fan"

品質 性能良好な防水レベル IP55/IP54の遠心風扇 工場

性能良好な防水レベル IP55/IP54の遠心風扇

Product Description: The 9-10.19 series centrifugal fan can output high gas pressure, suitable for conveying normal or high temperature clean gas/combustible gas/corrosive gas/mixed with a few impurities, light particles/debris/short fiber materials. The most commonly used for forced ventilation, rapid drying, rapid cooling and heat dissipation, cement production line chiller cooling, clinker cooler, circulating fluidized bed system, air purification and industrial waste gas

品質 強い吸着 Ss304 産業用ID 鋼鉄工場のための遠心風扇 工場

強い吸着 Ss304 産業用ID 鋼鉄工場のための遠心風扇

Product Description: Our Induced Draft Fan is equipped with advanced Impeller Testing technology that ensures dynamic balancing adjustment for optimal performance. This means that our fan is perfectly balanced and operates smoothly, reducing the risk of damage and extending the fan's lifespan. Additionally, our fan is designed to produce a noise level of ≤85dB(A), ensuring a safe and comfortable working environment for your employees. Our Induced Draft Fan is capable of

品質 信頼性の高い単一入口高圧 定製された工業ボイラー 引導式抽出風扇 セメント回転炉 工場

信頼性の高い単一入口高圧 定製された工業ボイラー 引導式抽出風扇 セメント回転炉

Product Description: The fan has high efficiency, low noise, flat performance curve and wide area of high efficiency. Engineered specifically for the extreme operating conditions of cement rotary kilns, this single inlet high pressure induced draft fan delivers exceptional reliability in handling high-temperature flue gases and abrasive dust particles. The robust construction features heat-resistant alloy components and specialized anti-wear protections, ensuring continuous

品質 発電所の高性能380V -10KVの産業ボイラー ファンFdファン 工場

発電所の高性能380V -10KVの産業ボイラー ファンFdファン

Industrial Boilers FD Fan Product description This industrial boiler FD fan are mainly applied in industrial boilers, like CFB boilers, steam boilers, coal fired boiler, biomass boilers, and so on. Blower fan, boiler draught fan, boiler smoke-exhaust fan, boiler primary air/secondry air/ circulating blower fan, and so on. Below boiler fd fan for your reference. Product parameter Performance Pressure range 3031---16205 Pa Air flow range 2065~316891 m3/h Impeller diameter 400

品質 高性能の産業ボイラーは吸出し送風機Y5-48-8C IDF 30KWのタイプを 工場

高性能の産業ボイラーは吸出し送風機Y5-48-8C IDF 30KWのタイプを

Industrial Boiler Induced Draft Fan (Y5-48-8C IDF 30 KW Type) Y5-48 Boiler Centrifugal Induced Fan Overview The Y5-48 boiler centrifugal fan is mainly used to meet the smoke exhaust requirements of the electric arc furnace exhaust gas purification equipment, improve the working environment of the workshop, and ensure that the dust concentration in the electric furnace and the working area comply with the "Industrial Enterprise Hygienic Standards". It can also be used in

品質 三相遠心送風機ファンの産業塵の送風機機械415V 440V 工場

三相遠心送風機ファンの産業塵の送風機機械415V 440V

Centrifugal Blower Fan (GY6-41) Application of Y6-41 Boiler Centrifugal Fan Y6-41 boiler centrifugal steam drum and induced draft fan are not suitable for 0.5~10t/h industrial boilers and low-noise boiler drums designed to burn various types of coal and equipped with dust removal devices. The efficiency of the induced draft fan is higher than 80%. In the case of comparable intake conditions, performance and suitability can be selected. GY6-41 Boiler Centrifugal Fan Applicatio

品質 600°Cの空気のためのY8-39 Y9-38のボイラー吸出し送風機3hpの集じん器の送風機 工場

600°Cの空気のためのY8-39 Y9-38のボイラー吸出し送風機3hpの集じん器の送風機

Circulating fluidized bed boiler fan Application of Y9-38 centrifugal induced draft Fan Model Y9-38 boiler centrifugal fan is designed for industrial boilers (0.5 ~ 35t/h) which are equipped with smoke and dust removal devices and burning various coal qualities. Where the intake conditions are the same and the performance is suitable, can be selected, but the maximum temperature shall not exceed 250℃. In front of the induced draft fan, the dust removal device must be added to

品質 5-55-12.5C電気分解アルミニウム高温遠心ファン110kw 68000の空気容積 工場

5-55-12.5C電気分解アルミニウム高温遠心ファン110kw 68000の空気容積

5-55-12.5C high temperature centrifugal fan Y5-55 boiler centrifugal induced draft fan product overview The centrifugal induced draft fan of Y5-55 boiler is designed for the industrial boiler (1 ~ 20T/h) which is equipped with smoke removal device and burning all kinds of coal. The maximum temperature shall not exceed 250℃ if the air intake condition is the same and the performance is suitable. Before the induced draft fan, the dust removal device with an efficiency of not

品質 ACモーター ガス送管の希薄の空気ファンの産業に遠心にOEMサービスを冷却ファン 工場

ACモーター ガス送管の希薄の空気ファンの産業に遠心にOEMサービスを冷却ファン

Flue Gas Dilution Fan Dilution Air Fan Dilution fan_Ammonia dilution fan desulfurization system The function of dilution fan Dilution fan The dilution fan dilutes the ammonia gas to a certain ratio and sprays it into the flue of the reactor to prevent the mixture of ammonia gas and air from reaching an explosive ratio, thereby causing danger. Each unit is equipped with two dilution fans, one conveyor and one backup. Dilution fan test run and chain protection Generally, the

前回
ページ 9 の 10
次へ